====== Provisioning Zebra TC5x devices ====== ===== ITF14, The barcodes on outer cartons do not scan. ===== {{ :automagic:install:zebra:itf14example.png?400 |}} Above is an example of an ITF14 barcode. If this style of barcodes are not scanning, you will need to enable Interleaved 2 of 5 symbols as follows: From the application drawer open the ''DataWedge'' application. - Click on the ''Profile0 (default)'' - Scroll down to ''Barcode input'' and select ''Configure scanner settings'' - Select ''Decoders'' - Scroll down to ''Interleaved 2 of 5'' - Set the ''Enabled'' check box - Set the ''Check Digit'' to ''USS Check Digit'' - Tick the box ''Report Check Digit'' You can test the scanner with the following two barcodes. The following barcode is a well formatted barcode and should scan. {{ :automagic:install:zebra:2of5-mod10.png?400 | This barcode should scan}} The following barcode has a bad check digit and **should not** scan. {{ :automagic:install:zebra:2of5-bad-check-digit.png?400 | This barcode **should not** scan.}} ===== The barcode only scans when the keyboard is on screen. ===== First try: From the application drawer open the ''DataWedge'' application. - Open the ''3-Dot'' menu and select ''Settings'' - Scroll to the bottom and select ''Restore''. This will reset the Data Wedge application to its factory settings. If you have previously enable Interleaved 2of5 barcode you will need to enter these settings again. ==If the above does not work you can try the following.== From the application drawer open the ''DataWedge'' application. - Click on the ''Profile0 (default)'' - Scroll down to ''Key stroke output'' and select ''Key event options'' - Under ''Characters'' select the option ''Send Characters as Events''